Faulty Signal - Intermittent Fault




Intermittent Fault







Check the cable between fuse 10 and ultrasonic sensor connector #6 for an intermittent open-circuit according to Checking wiring and terminals - Intermittent faults and contact resistance and oxidation according to Checking wiring and terminals - Intermittent faults.

Check the cable between ultrasonic sensor connector #7 and ground for an intermittent open-circuit according to Checking wiring and terminals - Intermittent faults.

Checking Wiring and Terminals - Intermittent Faults