Signal Too High. Intermittent Fault
Signal too high. Intermittent fault
Checking wiring and connectors
Check the signal cable between engine control module (ECM) #A13 and camshaft reset valve #2 for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Other information
- To connect the breakout box, see Connecting the breakout box, B5234T9, B5244T7 Connecting The Breakout Box.
- To access/replace the camshaft reset valve, see
- With the ignition on and camshaft reset valve connector disconnected the voltage on connector #1 should be approximately Ubat and connector #2 be a pulse modulated signal with top voltage at approximately Ubat and with a frequency of approximately 250 Hz.
- For information about signals, see Signal specification Signal Specifications.
Continue - Fault-tracing information
DONE
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Checking wiring and connectors
FAULT FOUND - DONE
-------------------------------------------------