Signal Missing. Intermittent Fault
Signal missing. Intermittent fault
Checking cables and connectors
Check EVAP canister shut-off valve connector for contact resistance and oxidation according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults and loose connections according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults
Check signal cable between control module #B40 (#B50) and EVAP canister shut-off valve terminal 2 and power supply between system relay terminal 3 and EVAP canister shut-off valve terminal 1 for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Other information
- Connecting the breakout box/accessing the control module, see Connecting the breakout box, B5234T9, B5244T7 Connecting The Breakout Box.
- To access/replace the EVAP canister shut-off valve see.
- For information about signals, see Signal specification Signal Specifications.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Checking cables and connectors
FAULT FOUND - DONE
-------------------------------------------------