Diagnostic Trouble Code (DTC) Information
Diagnostic trouble code (DTC) information
Condition
Diagnostic trouble code (DTC) ECM-4010 is stored if the signal from the EVAP canister shut-off valve is too high, too low or missing.
Substitute value
None
Possible source
Signal too high:
- short-circuit to supply voltage in the signal cable
- defective EVAP canister valve
Signal too low:
- short-circuit to ground in signal cable
Signal missing:
- open-circuit in signal cable
- defective EVAP canister valve
- contact resistance in terminals
- open-circuit in power cable
Fault symptom[s]
- Malfunction indicator lamp (MIL) lit.