Signal Too Low. Permanent Fault
Signal too low. Permanent fault
Checking connector
- Ignition off
- Check wiring and connectors for contact resistance and oxidation according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
- Reinstall components, reconnect connectors etc.
- Ignition on.
- Read off outside temperature.
If the temperature is now within its permitted range, the fault was caused by loose connections in the connector.
Other information
- To access/replace the outside temperature sensor see Replacing sensor Replacing Sensor.
Is the signal OK?
Yes - FAULT FOUND
No - Checking wiring and components
-------------------------------------------------
Checking wiring and components
Check outside temperature sensor resistance.
Note! The outside temperature sensor can be defective if the signal cable has been short-circuited to supply voltage. Check this before replacing the sensor.
Check signal cable between control module #B29 (#B39) and outside temperature sensor #1 for an intermittent open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault and a short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault
Hint: With the ignition on and the outside temperature sensor connector disconnected, the voltage between #1 and ground should be approximately 5 V.
Check the ground lead between control module #B2 (#B12) and the outside temperature sensor #2 for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault
Remedy as necessary.
Other information
- Connecting the breakout box/accessing the control module, see Connecting the breakout box, B5234T9, B5244T7 Connecting The Breakout Box.
- To access/replace the outside temperature sensor see Replacing sensor Replacing Sensor.
- For resistance values, see Component specifications [1][2]Engine Control Module.
- For information about signals, see Signal specification Signal Specifications.
Continue - Verification
-------------------------------------------------
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off.
- Reconnect connectors, reinstall components.
- Ignition on.
- Read off outside temperature.
Is the temperature within its permitted range?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFICATION FAILED - Fault-tracing information
VERIFIED - FAULT FOUND
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - Exit fault-tracing
No - Attempt New Test
------------------------
Attempt New Test - Checking connector
-------------------------------------------------