Faulty Signal. Intermittent Fault
Faulty signal. Intermittent fault
Checking connectors
Check fuel level sensor connector for contact resistance and oxidation according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Note! Vehicles with AWD. There are 2 fuel level sensors, one in each pump unit. The sensors are connected in series with each other.
Check combined instrument panel connector for contact resistance and oxidation in accordance with Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Remedy as necessary.
Other information:
- For information about signals, see Connector A, #A1 - #A30 , Connector B, #B1 - #B16 and Connector D, #D1 - #D5.
- Sensors [1][2]Instrument Panel, Gauges and Warning Indicators
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Checking connectors
FAULT FOUND - DONE
-------------------------------------------------