FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Current Too High. Intermittent Fault






Current too high. Intermittent fault

Mechanical check
Carry out the mechanical check according to Mechanical check Mechanical Check.

Was a fault found?

Yes - Fault-tracing information

No - Checking connectors and wiring

-------------------------------------------------

Checking connectors and wiring




- Ignition off
- Check control module connector D for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults
- Ignition on.
Connect a voltmeter in order between control module connector D4 and ground (motor for tensioner rib closing) and between D13 and ground (motor for the locking arms).
Check for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Remedy as necessary.

Other information:
- To access and replace the control module see Replacing the control module Service and Repair.









Was a short-circuit found?

Yes - Fault-tracing information

No - Checking the component

-------------------------------------------------

Checking the component




- Ignition off
- Check the relevant motor connector for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults
- Ignition on.
Connect a voltmeter in order between motor 1 and ground and between 2 and ground.
Check for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Replace the motor if a short-circuit is found.
If no fault is found, there is probably a short-circuit in the cable between the control module and the motor connectors.
Remedy as necessary.

Other information:
- To access or replace the motor for the tensioner rib see Replacing motors Service and Repair
- To access or replace the motor for the rear locking arms, see Replacing motors Service and Repair.





Was the fault found?

Yes - Fault-tracing information

No - No Fault Found

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).

Do you want to view the information again?

Yes - Attempt New Test

No - FAULT FOUND

------------------------

FAULT-TRACING FAILED - DONE

Attempt New Test - Mechanical check

-------------------------------------------------