Current Too High. Intermittent Fault
Current too high. Intermittent fault
Mechanical check
Carry out the mechanical check according to Mechanical check Mechanical Check.
Was a fault found?
Yes - Fault-tracing information
No - Checking connectors and wiring
-------------------------------------------------
Checking connectors and wiring
- Ignition off
- Check control module connector D for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults
- Ignition on.
Connect a voltmeter in order between control module connector D4 and ground (motor for tensioner rib closing) and between D13 and ground (motor for the locking arms).
Check for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Remedy as necessary.
Other information:
- To access and replace the control module see Replacing the control module Service and Repair.
Was a short-circuit found?
Yes - Fault-tracing information
No - Checking the component
-------------------------------------------------
Checking the component
- Ignition off
- Check the relevant motor connector for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults
- Ignition on.
Connect a voltmeter in order between motor 1 and ground and between 2 and ground.
Check for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Replace the motor if a short-circuit is found.
If no fault is found, there is probably a short-circuit in the cable between the control module and the motor connectors.
Remedy as necessary.
Other information:
- To access or replace the motor for the tensioner rib see Replacing motors Service and Repair
- To access or replace the motor for the rear locking arms, see Replacing motors Service and Repair.
Was the fault found?
Yes - Fault-tracing information
No - No Fault Found
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
FAULT-TRACING FAILED - DONE
Attempt New Test - Mechanical check
-------------------------------------------------