Signal Too Low. Intermittent Fault
Signal too low. Intermittent fault
Checking connectors and wiring
- Ignition off
- Check the convertible control unit connector A. Check for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Connect an ohmmeter between convertible control unit control module terminal #A17 and ground.
Take a reading for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Check the ECC control module connector A. Check for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Remedy as necessary.
Other information:
- To access or replace the convertible control unit, see Replacing the control module Service and Repair
- To connect the breakout box, see Connecting the convertible control unit breakout box Connecting the Breakout Box
Select Continue when the fault has been remedied.
Continue - Fault-tracing information
DONE
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
FAULT-TRACING FAILED - DONE
Attempt New Test - Checking connectors and wiring
-------------------------------------------------