General Faults / Parameter Faults. Permanent Fault
General faults / Parameter faults. Permanent fault
Checking the function of the convertible top
- Ignition on
- Parking brake applied
- The trunk lid is closed
- Speed < 4 km/h.
Activate the control switch for convertible top operation.
If the convertible top cannot be operated, try installing a new control module.
Other information:
- To access or replace the control module, see Replacing the control module Service and Repair.
Select Continue when the fault has been remedied.
Continue - Calibrating the convertible system
-------------------------------------------------
Calibrating the convertible system
It is important that the control module is calibrated and programmed if the control module has been replaced.
Program and calibrate according to Programming and calibrating the convertible system Programming and Relearning.
Continue - Verification
-------------------------------------------------
Verification
Verification
Hint: After the repair it is necessary to check that the fault has been rectified.
- Ignition off
- Connect the connectors, install the components, etc.
- Ignition on
- Apply parking brake
- Close the luggage compartment lid
- Speed < 4km/h.
Operate the control switch to move the convertible top.
Move the convertible top to its end positions.
Does the convertible top work?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFICATION FAILED - Fault-tracing information
VERIFIED - FAULT FOUND
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - Exit fault-tracing
No - Attempt New Test
------------------------
Attempt New Test - Checking the function of the convertible top
-------------------------------------------------