3. Checking Wiring and Components
Checking Wiring And Components
Check cable between control module #A37 and transmission connector (control module side) #12 for a short-circuit to ground according to Checking wiring and terminals. Permanent faults.
HINT: With the ignition off and the transmission connector disconnected the resistance between #12 and #13 should be 765-1035 Ohms at 20 degree C (68 degree F). At other transmission temperatures, see table Component resistance values. With the control module and transmission connectors disconnected the resistance between control module #A37 and #A55 should be infinite.
Remedy as necessary.
Other Information:
- To connect the breakout box, see Connecting breakout box, Transmission control module (TCM).
- To disconnect transmission connector, see Inspecting/cable harness to solenoids.
- To check/replace oil temperature sensor, see Replacing the oil temperature sensor.
- For information about signals, see Signal specification, Transmission control module (TCM).
Was a fault detected?
YES: Refer to Resetting the Adaptation. 4. Resetting the Adaptation
NO: Refer to Trouble Code Descriptions. Diagnostic Trouble Code Descriptions