Upper Left Coolant Pipe
Upper Left Coolant Pipe
Removing
- Drain the coolant. Refer to => [ Coolant, Draining ] Coolant, Draining.
- Remove the EGR cooler switch-over valve (- 1 -) from the bracket.
- Remove the bolt - 4 - and the engine cover ball stud - 2 -.
- Free up the wiring harness - 3 - on the top of the coolant pipe on the left side.
- Loosen the clamps - arrows - and remove the upper left coolant pipe.
Installing
Install in the reverse order of removal. Note the following:
Tightening specifications, refer to => [ Coolant Pipes Overview ] Coolant Pipes Overview.
• Secure all hose connections using hose clamps appropriate for the model type.
- Fill the coolant. Refer to => [ Coolant, Filling ] Coolant, Filling.