Plenum Chamber Bulkhead
Plenum Chamber Bulkhead
Removing
• The center portion of the plenum chamber bulkhead can only be removed when the two side parts are removed.
Perform the following:
For the left plenum chamber bulkhead
- Remove the bolts - 3 -.
- Lift out the left plenum chamber bulkhead - 2 - with the seal - 4 -.
For the right plenum chamber bulkhead
- Remove the bolts - 9 -.
- Lift out the right plenum chamber bulkhead - 8 - with the seal - 7 -.
For the center plenum chamber bulkhead
• The left and right plenum chamber bulkheads are removed.
- Remove the bolts - 6 -.
- Remove the hex nuts - 5 -.
- Lift out the center plenum chamber bulkhead - 1 -.
Installing
• The center plenum chamber bulkhead is installed first.
• When installing the left and right plenum chamber bulkheads, make sure the seal is seated correctly.
Perform the following:
For the center plenum chamber bulkhead
- Install the center plenum chamber bulkhead - 1 -.
- Tighten the nuts - 5 -, tightening specification: 6 Nm.
- Tighten the bolts - 6 -, tightening specification: 6 Nm.
For the left plenum chamber bulkhead
- Install the left plenum chamber bulkhead - 2 - with the seal - 4 -.
- Tighten the bolts - 3 -, tightening specification: 6 Nm.
For the right plenum chamber bulkhead
- Install the right plenum chamber bulkhead - 8 - with the seal - 7 -.
- Tighten the bolts - 9 -, tightening specification: 6 Nm.