Crankshaft Radial Clearance, Measuring
Crankshaft Radial Clearance, Measuring
Special tools, testers and auxiliary items required
• Plastigage(R)
Conditions:
• Do not rotate the crankshaft when checking the radial clearance.
Test Sequence:
• Do not interchange used bearings.
• Bearing shells that are worn down to the nickel layer must be replaced.
- Remove the main bearing cap, clean the bearing cap and journal.
- Place the Plastigage(R) over the entire width of the bearing journal or into the bearing cap.
• The Plastigage(R) must rest in the center of the bearing shell.
- Install and tighten the main bearing cap. Do not rotate the crankshaft while doing this.
- Remove the main bearing cap again.
- Compare the width of the Plastigage(R) with the calibrated scale.
Radial clearance:
New: 0.02 to 0.06 mm
Wear limit: 0.10 mm