Ribbed Belt Pulley Without Free-Running Hub
Ribbed Belt Pulley Without Free-Running Hub
Special tools, testers and auxiliary items required
• Socket (VAS 3310)
• Torque Wrench (V.A.G 1332)
Removing
- Remove the generator. Refer to 2.5L => [ Generator ] Generator, 3.6L => [ Generator ] Generator or TDI => [ Generator ] Generator.
- Secure the generator in a vice by the mounting points.
- Remove the ribbed belt pulley nut from the generator shaft using the (VAS 3310).
Installing
Install in reverse order of removal. Note the following:
- Tighten the threaded connection to 65 Nm.