Flat Connector Systems






Flat Connector Systems

Housing securing mechanisms (secondary locks) must be released or removed using specified tool before releasing the contacts, refer to => [ Secondary Lock ] Secondary Lock.

Flat Connector System With One Retaining Tab





- Guide the release tool which fits the terminal housing into release channel on terminal housing.

- Grasp contact at wire and push it gently into terminal housing - arrow -.

By pushing contact in direction of terminal housing, contact retaining tab is lifted off the housing shoulder and can be released using the release tool.

- At the same time, push release tool in direction of terminal housing and pull the released contact out of terminal housing - arrow -.






- After removing the contact, release tool can be pulled out of terminal housing again.

Flat Connector System With Two Retaining Tabs

- Guide the release tool which fits the terminal housing into release channel on terminal housing.






- Grasp contact at wire and push it gently into terminal housing until it stops - arrow -.

By pushing contact in direction of terminal housing, contact retaining tabs are lifted off the housing shoulder and can be released using the release tool.

- At the same time, push release tool in direction of terminal housing and pull the released contact out of terminal housing - arrow -.






- After removing the contact, release tool can be pulled out of terminal housing again.

Asymmetrical

- Guide the release tool which fits the terminal housing into release channel on terminal housing.






- Grasp contact at wire and push it gently into terminal housing - arrow -.

By pushing contact in direction of terminal housing, contact retaining tabs are lifted off the housing shoulder and can be released using the release tool.

- At the same time, push release tool in direction of terminal housing and pull the released contact out of terminal housing - arrow -.






- After removing the contact, release tool can be pulled out of terminal housing again.