New Control Module, Installing
New Control Module, Installing
Excessive shaking (e.g. dropping, impact) may destroy the control module. Control module must then no longer be used.
• Surface must be cleaned before assembling.
- Slide all sealing rings - A - slightly over the valve dome.
- Place control module without canting it onto hydraulic unit.
Sealing rings are then brought into their end position.
- Install the hydraulic unit and control module with the new inner Torx bolts diagonally according to the tightening specification.
• A new control module may be installed a max. of two times to a used hydraulic unit, to ensure that the elastic gasket seals sufficiently.
• A control module which was once in driving operation must not be installed a second time.