EGR Temperature Sensor G98
EGR Temperature Sensor G98
Special tools, testers and auxiliary items required
• Hose Clamps Up to 25 mm Dia. (3094)
• Torque Wrench (5-50 Nm) (V.A.G 1331)
• Drip Tray for VAS 6100 (VAS 6208)
• Hose Clip Pliers (VAS 6362)
• 14 mm Socket (T10401)
Requirements
• The ignition is off.
• The engine must be cold.
Procedure
- Remove the noise insulation.
- Drain the coolant. Refer to => [ Draining and Filling ] Draining and Filling.
• The coolant hoses indicated must be removed and moved to the side to perform assembly work on the Exhaust Gas Recirculation (EGR) temperature sensor.
- Disconnect the coolant hoses from both connections - arrows A and D -.
- Lay aside both coolant hoses - arrows B and C - as illustrated.
- Remove the engine cover. Refer to => [ Engine Cover ] Engine Cover.
Electronic components could be destroyed when the battery is disconnected:
• Follow the required steps when disconnecting the battery.
- With the ignition turned off, disconnect the ground cable - arrow - from the battery.
- Remove the air filter housing. Refer to => [ Air Filter Housing ] Air Filter Housing.
- Remove the battery, the battery tray bolts - arrows - and tray.
- Disconnect the connector from the EGR temperature sensor - arrow A - and guide the wire out.
• Note the installation location of the lines and heat shield.
The illustration shows the EGR temperature sensor as seen from the engine compartment looking out from the transmission side - arrow - below the brake master cylinder.
- Carefully guide the 14 mm socket (T10401) with an extension onto the EGR temperature sensor.
- Make sure the wire from the EGR temperature sensor is guided into the groove on the 14 mm socket (T10401) - arrow A -.
- Loosen the EGR temperature sensor and remove it.
Installing
- Install in the reverse order of removal. When doing this note the following:
• EGR temperature sensor tightening specification: 20 Nm
• Cut off the gasket and replace if it is damaged or leaks
• Maintain the tightening specification.
Install the heat shield mats in their original locations.
Make sure the entire connection is seated securely.
Always replace self-locking nuts, seals, gaskets and clamps.
Hoses are secured with spring type clamps.
hose clip pliers (VAS 6362) or (VAS 6340) are recommended for installing spring type clamps.