Firewall: Service and Repair
Cross Panel
• Cross panel - 1 - is bolted and also bonded in with PUR adhesive sealing material - 3 -.
1 Cross panel
• Removal:
- Cut through the bead of adhesive - 3 - after removing the screws - 2 -.
2 Body flange
3 PUR adhesive sealant
• DH 009 100 03
• Bead cross section: Width = 8 mm height = 10 mm
• Minimum curing time, refer to=> [ Minimum Curing Time ] Minimum Curing Time
4 Bolt
• Quantity: 10
• Tightening specification: 25 Nm