FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Charge Air System, Checking for Leaks






Charge Air System, Checking for Leaks

Special tools, testers and auxiliary items required

Adapter (V.A.G 1687/5)

Testing Unit for Turbocharger (V.A.G 1687)

Ultrasonic Measuring Device (V.A.G 1842) or Commercially Available Leak Detection Spray

Test Sequence

- Remove the noise insulation..

- Release the clamp - A - and disconnect the hose - B - from the charge air pipe.






- Connect the adapter (V.A.G 1687/5) to the charge air hose - A - and rotate it around approximately 90° - B -.






Prepare the testing unit for turbocharger (V.A.G 1687) as follows:






- Turn the pressure regulator valve - 2 - counterclockwise until it stops.

- Close the valves - 3 and 4 -.

In order to be able to turn the pressure regulator valve - 2 -, the rotary knob must be pulled upward.

- Connect the testing unit for turbocharger (V.A.G 1687) as shown.






- Connect a compressed air hose - 1 - (pressurized air supply) to the testing unit for turbocharger (V.A.G 1687).






If water is located in the viewing glass, drain it via the water drain plug - 6 -.

- Open the valve - 3 -.

- Set the pressure to 0.5 bar using the pressure regulator valve - 2 -.

Pressure must not exceed 0.5 bar! A pressure set too high may damage the engine.

- Open the valve - 4 - and wait until the testing circuit has filled. If necessary, continue to regulate pressure to 0.5 bar.

- Check the charge air system for poorly sealed areas by listening, feeling, using a leak detection spray or by using the ultrasonic measuring device (V.A.G 1842).

Charge air hose installing. Refer to => [ Charge Air Hose, Disconnecting and Connecting ] Charge Air Hose, Disconnecting and Connecting.

A small quantity of air dissipates via the valves in engine. A pressure retention test is not possible for this reason.

Handling instructions of the ultrasonic measuring device (V.A.G 1842). Refer to the operating instructions.

Before removing the adapter, discharge the pressure in the testing circuit by pulling off the coupling from the adapter (V.A.G 1687/5).

Hose connections and charge air system hoses must be free of oil and grease before installing.