Crankshaft Radial Clearance, Checking
Crankshaft Radial Clearance, Checking
Special tools, testers and auxiliary items required
• Plastigage(R)
Conditions
• Do not rotate the crankshaft when checking the radial clearance.
Test Sequence
• Do not interchange used bearing shells.
• Bearing shells that are worn down to the nickel layer must be replaced.
- Remove the main bearing cap and clean the cap and journal.
- Place the Plastigage(R) over the entire width of the bearing journal or into bearing shell.
• The Plastigage(R) must rest in the center of the bearing shell.
- Position the main bearing cap and tighten the bolts to 60 Nm. Do not rotate the crankshaft when doing so.
- Remove the main bearing cap bolts and cap again.
- Compare the width of the Plastigage(R) with the measuring scale.
Radial clearance:
New: 0.017 to 0.037 mm
Wear limit: 0.15 mm