After-Run Coolant Pump (V51)
After-Run Coolant Pump (V51)
Special tools, testers and auxiliary items required
• Hose Clamps up to 25 mm Dia. (3094)
• Hose Clip Pliers (VAS 6362)
Removing
Risk of scalding due to hot steam and hot coolant:
• The coolant system is under pressure when the engine is warm.
• Wear protective goggles and protective clothing to prevent damage to eyes and scalding.
• Reduce pressure by covering the coolant expansion tank cap with a cloth and carefully opening.
- Open the coolant expansion tank cap.
- Remove the noise insulation..
- Disconnect the after-run coolant pump connector - 1 -.
- Place the drip tray for VAS 6100 (VAS 6208) under the engine.
- Clamp off the coolant hoses to the after-run coolant pump using the hose clamps up to 25 mm dia. (3094)
- Reposition the hose clamps - arrows - and disconnect the coolant hoses.
- Remove the after-run coolant pump bracket bolt - 2 -.
Installing
• Tightening specifications, refer to => [ After-Run Coolant Pump (V51) Overview ] After-Run Coolant Pump (V51) Overview.
Install in reverse order of removal. Note the following:
- Check the coolant level. Refer to => [ Coolant, Draining and Filling ] Service and Repair.