Connecting Rod: Testing and Inspection
Connecting Rod Radial Clearance, Checking
Special tools, testers and auxiliary items required
• Plastigage(R)
Sequence
- Remove the connecting rod bearing cap. Clean the bearing cap and journal.
- Place the Plastigage(R) over the entire width of the bearing journal or in the bearing cap.
- Install the connecting rod bearing cap and tighten the bolts to 30 Nm. Do not rotate the crankshaft.
- Remove the connecting rod bearing cap again.
- Compare the width of the Plastigage(R) with the measuring scale:
Radial clearance, new:
0.015 to 0.062 mm
Radial clearance wear limit:
0.12 mm
- Replace the connecting rod bearing cap bolts.