Camshaft: Testing and Inspection
Camshaft Axial Clearance, Checking
Special tools, testers and auxiliary items required
• Dial Gauge Holder (VW 387)
• Dial Gauge 0-10 mm (VAS 6079)
Sequence
- Perform the measurement with the cylinder head cover removed.
- Place the camshaft to be checked in the cylinder head.
- Secure the dial gauge 0-10 mm (VAS 6079) to the cylinder head using the dial gauge holder (VW 387).
- Press the camshaft against the dial gauge by hand.
- Set the dial gauge to "0".
- Press the camshaft off the dial gauge and read the value:
• Axial clearance: 0.05 to 0.17 mm.