Recirculation Door Motor (V113)
Recirculation Door Motor (V113)
Removing
- Remove the glove compartment. Refer to Storage Compartments, Covers and Trim.
- Remove the adjustment motor cover - 1 -.
- Disconnect the connector from the recirculation door motor - 2 -.
- Remove recirculation door motor - 2 -.
Installing
Install in reverse order of removal.
• After installing, function of recirculation door must be checked.
• Initiate "Basic Setting" function with Vehicle Diagnostic Tester. Refer to => [ Climatronic A/C System with Automatic Controls, Checking and Adjusting Components ] Climatronic A/C System with Automatic Controls, Checking and Adjusting Components.