Leak Detection Pump: Service and Repair
EVAP Canister and Leak Detection Pump
Removing
- Remove the rear right wheel housing liner.
- Disconnect the vent lines - 1 and 2 -.
Press in the securing ring - A - to disengage the lines.
- Disconnect the connector - 3 -.
• Illustration shows a metal fuel tank. Steps for the plastic fuel tank are similar.
- Disconnect the vacuum line - 3 -.
- Remove the right rear side turn signals.
- Remove the bolt - 3 -.
- Remove the bolts - 1 and 2 -.
- Remove the Evaporative Emission (EVAP) canister with the Leak Detection Pump (LDP) (V144).
Removing the LDP
- Disconnect the connecting hose from the LDP.
- Remove the three bolts.
- Remove the LDP from the EVAP canister
Installing
Installation is performed in the reverse order of removal. When doing this note the following:
• Connect ventilation lines until they engage audibly.
• Make sure lines and EVAP canister are locked securely.
Tightening Specifications