Air Injection Control Valve: Service and Repair
Secondary Air Injection Solenoid Valve, Checking
Special tools, testers and auxiliary items required
• Connector test set (VAG 1594C)
• Assisting hose, for example, coolant hose
Sequence
• Do not use compressed air during the following check!
- Remove the engine cover.
- Disconnect the pressure hose - 2 - from Secondary Air Injection (AIR) solenoid valve (N112) - 3 -. To do so, compress the securing ring.
- Disconnect the harness connector - 4 -.
- Slide the assisting hose - 1 -, for example, coolant hose, into the AIR solenoid valve.
- Blow forcefully into the assisting hose - arrow -.
Valve must be closed.
If air can be blown through the valve with the assisting hose properly sealed:
- Replace the AIR solenoid valve.
If valve is closed:
- Connect terminals on the connector connection - 5 - with adapter cables from (VAG 1594C) to the battery positive (+) and negative (-).
- Blow forcefully into the assisting hose - arrow -.
Valve must be opened.
If no air can be blown through the valve with the assisting hose properly sealed:
- Replace the AIR solenoid valve.