Variable Valve Timing Cover / Housing: Description and Operation
Control Housing Overview
1 Guide Rail
• Clipped onto the control housing.
2 Control Housing
3 Camshaft Adjustment Valve 1 (N205)
• Removing and installing, refer to => [ Camshaft Adjuster Valves ] Camshaft Adjuster Valves.
4 Camshaft Adjustment Valve 1 (Exhaust) (N318)
• Removing and installing, refer to => [ Camshaft Adjuster Valves ] Camshaft Adjuster Valves.
5 Bolt
• 8 Nm
• Install using locking fluid (D 000 600 A2).
Checking Control Housing Strainer for Contaminants
- Unclip the strainer - 2 - from the rear side of the control housing - 1 - and remove any possible contamination.