3.2L, 3.6L
Generator, Coolant Cooled Overview
1 - Tension Roller
2 - Hex Socket Head Bolts
• 20 Nm
• M8 x 30 mm
3 - Fitting Bolts
• M8 x 28 mm
• 20 Nm
4 - Bracket
5 - Coolant Hose
• Connection diagram for coolant hoses, refer to => Engine Mechanical, Fuel Injection and Ignition 19 Description and Operation.
6 - Clamp
7 - Torx(R) Flat Head Bolt
• 9 Nm
• M6 x 16 mm
8 - Connecting Piece
9 - O-ring
• Always replace
10 - Generator
• B+ wire fastener to generator, 15 Nm, refer to => [ B+ Cable Mount on Generator ] Procedures.
• Neither the voltage regulator nor the carbon brushes can be replaced individually; if a repair is required, the entire generator must be replaced.
• Generator, removing and installing, refer to => [ Generator, Coolant Cooled ] Generator, Coolant Cooled.
11 - Ribbed Belt
• Checking ribbed belt, refer to => [ Ribbed Belt, Checking ] Testing and Inspection.
• Ribbed belt routing, refer to => [ Ribbed Belt Routing, Generator, Coolant Cooled ] Ribbed Belt Routing, Generator, Coolant Cooled.
12 - Collar Bolts
• 20 Nm
• M8 x 90 mm
13 - Idler Pulley
14 - Bolt
• 20 Nm
• M10 x 45 mm
15 - Cap
16 - Hex Socket Head Bolts
• 20 Nm
• M8 x 30 mm