Free-Wheel Belt Pulley
Special tools, testers and auxiliary items required
• Torque Wrench (V.A.G 1332)
• Multi-Point Adapter (VAS 3400)
Removal
- Remove generator. Refer to=> [ Generator, Air Cooled ] Generator, Air Cooled or => [ Generator, Coolant Cooled ] Generator, Coolant Cooled.
- Tighten the generator in a vise at the attachment points.
- Remove the protective cap from the free-wheeling belt pulley.
- Insert the multi-point adapter 3400 - 1 - with a 17 mm open-end wrench into the free-wheeling belt pulley - 2 - of the generator. Then, insert a multi-point socket insert M10 - 3 - into the generator shaft.
- Hold the generator shaft and loosen the ribbed belt pulley with freewheel by turning it to the left using an open-end wrench.
- Hold the free-wheeling belt pulley firmly by hand and rotate it on the generator driveshaft until the free-wheeling belt pulley can be removed.
Installation
Install in reverse order of removal. Note the following:
- First tighten the free-wheel belt pulley on the generator driveshaft by hand until the pulley stops.
Torque wrench must be reassembled for installing overrunning clutch pulley as follows:
- Release the insert - 1 - and pull it from the handle - 2 -.
- Rotate the handle - 2 - of the torque wrench 180 degrees and re-insert the bit.
- Set the rotation direction of the torque wrench bit to "left."
- Counterhold multi-point adapter 3400 - 1 - using open end wrench 17 mm and tighten overrunning clutch pulley by turning generator driveshaft toward left using torque wrench - 2 -. The tightening specification is 80 Nm.
- Clip the protective cap onto the free-wheeling belt pulley.