Camshaft: Testing and Inspection
Camshaft Axial Clearance, Checking
Special tools, testers and auxiliary items required
• Dial Gauge Holder (VW 387)
• Dial Gauge (0-10 mm) (VAS 6079)
Intake Camshaft
- Take the measurement when the guide frame is removed.
• Target value: 0.03 to 0.08 mm
• Wear limit 0.12 mm
Exhaust Camshaft
- Take the measurement when the guide frame is removed.
• Target value: 0.03 to 0.08 mm
• Wear limit 0.12 mm