Heating, Ventilation
Central Door Cable
Cable sleeve marking: Yellow
Prerequisite
• Central door lever correctly adjusted => [ Central Door Lever ] Service and Repair.
• Heating and ventilation controls are installed.
• Connecting duct removed => [ Connecting Duct ] Service and Repair.
Installing and adjusting
- Turn air distribution rotary control knob to left onto stop.
- Attach center wire of cable - 2 - to the central door lever - 1 -.
- Press footwell/defrost door lever onto stop arrow - A - and attach outer cable - 2 - with clip - 3 -.
- Turn air distribution rotary control knob to left and right onto stops.
When turning the rotary control knob both end stops must be reached.