FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Battery, Charging



Battery Charger VAS 5900

CAUTION:
- Risk of injury. Observe warning notes and safety precautions.
- Batteries that have a colorless or light yellow visual indicator must not be tested or charged. Jump starting must not be used
- There is a risk of explosion during testing, charging or jump starting.
- These batteries must be replaced.


In this chapter, the base functions of the battery charger VAS 5900 are described. More information can be found in the operating instructions of the battery charger VAS 5900.

NOTE:
- The effective charging current can be read out directly on this charging device.
- Observe the operating instructions of the battery charger VAS 5900.

Battery, Charging

CAUTION:
- Risk of injury. Observe warning notes and safety precautions.
- Batteries that have a colorless or light yellow visual indicator must not be tested or charged. Jump starting must not be used
- There is a risk of explosion during testing, charging or jump starting.
- These batteries must be replaced.


Special tools, testers and auxiliary items required
- Battery Charger VAS 5903 VAS 5900

NOTE: The battery temperature must be at least 10 degrees C.

- Turn off the ignition and all electrical consumers.
- Plug in the electrical system connector of the charger. The last selected battery type is shown on the display.







- Using INFO, set the mode of operation that corresponds with the battery.

The symbol - 1 - for "standard charge of wet batteries" or the symbol - 2 - for "standard charge of Gel/Absorbent Glass Mat (AGM) batteries" is indicated in the display.

- Set the capacity (Ah) of the battery to be charged with the corresponding button "Up" arrowup or "Down" arrowdown.
- Clamp the red charging clamp "+" to the positive battery terminal.
- Clamp the black charging clamp "-" to the negative battery terminal.

The charger recognizes the nominal voltage of the connected battery (6 V, 12V, or 24 V) and begins the charging process automatically.







At a charge condition of approximately 80 - 85%, charging unit begins the "Final-charging". The fourth bar is indicated on the display - 1 -. The battery is ready for operation.







With a charge status of 100%, all bars are indicated on the display.

NOTE:
- With the battery type "standard charge", parallel operation of consumers during the charging process is possible. The charging time is lengthened by this.
- Depending on battery type, the charger switches over to sustain charging after approximately 1-7 hours. To achieve a 100% charge status, the battery should remain connected to the charger for that long.

Possible malfunctions and how they are handled:
1 Displayed voltage does not match the nominal voltage: Hold the appropriate button Up (UP arrow) or Down (Down arrow), until the charging process begins. Displayed battery voltage does not match the nominal voltage - the charging process has already begun: Press START / STOP twice. Hold the appropriate button Up (UP arrow) or Down (Down arrow) until the charging process begins again. The charger does not recognize a battery, when the battery voltage is less than 2 V: The display remains unchanged. The selected battery type and Ampere hours (Ah) are displayed.

End battery charging process:
- Press START / STOP.
- Remove the black charging clamp "-" of the charger from the negative battery terminal.
- Remove the red charging clamp "+" of the charger from the positive battery terminal.
- Pull out the electrical system connector of the charger.