Camshaft: Testing and Inspection
Camshaft, Checking Axial Clearance
Special tools, testers and auxiliary items required
• Dial Gauge Holder (VW 387)
• Dial Gauge (0-10 mm) (VAS 6079)
Test Sequence:
- Perform the measurement with the cylinder head cover removed.
- Place the camshaft to be checked in the cylinder head.
- Secure the dial gauge (0-10 mm) (VAS 6079) to the cylinder head using dial gauge holder (VW 387).
- Press the camshaft against the (VAS 6079) by hand.
- Set the (VAS 6079) to "0".
- Press the camshaft off the (VAS 6079) and read the value:
• Axial play: 0.05 to 0.17 mm.