After-Run Coolant Pump (V51)
After-Run Coolant Pump (V51)
Special tools, testers and auxiliary items required
• Hose Clamps Up to 25 mm Dia. (3094)
• Hose Clip Pliers (VAS 6362)
Removing
Risk of scalding due to hot steam and hot coolant.
• When the engine is warm the cooling system is under pressure.
• Reduce pressure by covering the coolant expansion tank cap with a cloth and carefully opening.
- Open the coolant expansion tank cap.
- Remove the noise insulation.
- Disconnect the electrical connector - 1 - from the after-run coolant pump.
- Place (VAS 6208) under the engine.
- Disconnect the coolant hoses - arrows - together with the hose, clamp off using (3094).
- Remove the coolant hoses from the after-run coolant pump.
- Remove the bolt - 2 - and the after-run coolant pump.
Installing
• Tightening specifications, refer to => [ After-Run Coolant Pump Overview ] After-Run Coolant Pump Overview.
Installation is performed in reverse order of removal, noting the following:
- Check the coolant level.