Headlamp Alignment Sensor: Adjustments



Left Front Level Control System Sensor, Adjusting

Special tools, testers and auxiliary items required
- Scan Tool VAG 1551 / VAG 1552 (ST) or Vehicle Diagnostic Testing and Information System VAS 5051 / VAS5052.
- Adapter Cable VAG 1551/3B

Prerequisites
- Vehicle must be standing on all four wheels on a flat level surface.
- Handbrake lever must be in off position and a drive gear must not be selected.
- Steering must be in straight-ahead position.
- Vehicle must be unoccupied and not loaded.
- Vehicle must not be moved during basic settings process ( i.e.: opening and closing of doors, people leaning on vehicle, people entering vehicle is not permitted).
- If vehicle was raised using a lifting platform/hoist or a vehicle/workshop jack, then it must be rolled back and forth several times so that the springs etc. settle, before starting adjustments.

Vehicle Diagnostic Testing and Information System VAS 5051/VAS 5052, Selecting Functions

Scan Tool VAG 1551/VAG 1552, Connecting and Selecting Functions (Function 01)

Prerequisites:
- All fuses OK., according to wiring diagram
- Voltage supply OK. (minimum 9.0 V).







- Connect Scan Tool (ST) using Adapter Cable VAG 1551/3B .

Indicated on display: anm3522885941127-s1
VAG- SELF-DIAGNOSIS HELP
1 - Rapid data transfer*


Indicated on display: anm3522885941127-s1
VAG- SELF-DIAGNOSIS HELP
2 - Flash code output*


Appears alternately

NOTE:
- If display remains blank, check Scan Tool VAG 1551 / VAG1552 voltage supply according to wiring diagram.
- Additional operating instructions can be called up with the scan tool HELP key.
- The arrowright key advances the program sequence.
- In operating mode 1 "Rapid data transfer" function 00 "Automatic test sequence" can be carried out. The DTC memory of all vehicle control units is checked automatically with function 00..

- Switch ignition on.
- Switch printer on with the Print key (warning lamp in the key will light up).
- Press key 1 for "Rapid data transfer" operating mode.

Indicated on display:
Rapid data transfer HELP
Enter address word XX


- Press keys 2 and 9 to select "Light control, left" address word "29".

Indicated on display:
Rapid data transfer Q
29 Light control, left


- Press Q button to confirm input.

Indicated on display:
Rapid data transfer Q
Tester sends address word 29


Control Module Version, Checking

Indicated on display:
7M3907391 EVG GDL + Auto HRC 0001->
Coding 00006 WSC 00000


Upper line:
- Part No. of control module anm3522885941130-1b
- System designation (headlamp range control)
- Version number anm3522885941130-1b

Bottom line:
- Coding number anm3522885941130-2b
- Dealership number

Part and version numbers illustrated here are examples only
Dependent on type of drive

- Press arrowright key.

Indicated on display:
Rapid data transfer HELP
Select function XX


- Press keys 0 and 8 to select "Read measuring value block" address word 08.

Indicated on display:
Rapid data transfer Q
08 - Read measuring value block


- Press Q button to confirm input.

Indicated on display:
Read measured value block
Enter display group number XXX


- Press key 0 twice and press key 2 once to select display group number 002.
- Press Q button to confirm input.

Indicated on display e.g.:
Read measuring value block 2 ->
2.1 2.4 ADP. O.K.








- Loosen lower securing bolt - arrow - on coupling rod of front axle.
- Move coupling rod within elongated hole until specification of 1.0 to 2.0 Volt is displayed in display zone 1 of the Read measuring value block. Optimum specification = 1.0 Volt (if possible).
- Tighten securing bolt. When doing this ensure voltage remains as close to optimum tolerance of 1.0 Volt as possible.

Indicated on display after completion of adjustments e.g.:
Read measured value block 2 ->
1.0 2.2 ADP. O.K.


- Press arrowright key.

Indicated on display:
Rapid data transfer HELP
Select function XX


- Press keys 0 and 6 to select "End output" function 06.

Indicated on display :
Rapid data transfer Help
Enter address word XX


After completing the mechanical adjustment of coupling rod, the related electrical components must be adjusted to the revised settings. Perform basic settings of the automatic headlamp range control to adjust to the revised settings.