Coolant Fan, Checking
Coolant Fan, Checking
Special tools, testers and auxiliary items required
^ Connector test set V.A.G 1594 A
^ Wiring diagram
Test requirements
^ Main fuses must be OK.
^ Coolant Fan Control (FC) Thermal Switch F18 OK.
Test sequence
- Disconnect connector on Coolant Fan Control (FC) Thermal Switch F18.
- Bridge terminal 1 and terminal 2 of connector with adapter cables from V.A.G 1594 A.
- Stage 1 of Coolant Fan V7 must start up.
- Switch ignition on.
- Bridge terminal 2 and terminal 3 of connector with adapter cables from V.A.G 1594 A.
- Stage 2 of Coolant Fan V7 must start up.
If 1st or 2nd speeds of fans do not run:
- Locate and repair open circuit in wiring using wiring diagram.
If no fault is detected in the wiring:
- Replace Coolant Fan V7.