Ribbed Belt, Without Automatic Tensioner, Adjusting Tension
03 - Service Procedures
Ribbed Belt, without Automatic Tensioner, Adjusting Tension
Special tools, testers and auxiliary items required
• Clamping Lever (3297)
- Loosen the bolts - 1 + 2 -.
3 Clamp
4 Generator
- Insert clamping lever, secure with pin - arrow - and tip generator down (use e.g. torque wrench as drive for 3297).
- Press generator as far as clamp stop at least three times using clamping lever to ensure optimum ease of movement.
- Tighten first the lower, then the upper generator bolt to 25 Nm.