Small Trim, Adjusting
Pillar and Side Trims, Convertible
Small Trim, Adjusting
Large and small trim borders may have different gap dimensions with respect to side trim borders.
- Gap dimensions - C -, - D - should be between 3.5 and 4.5 mm to avoid jamming or damaging when opening or closing the trims.
The small trim may show a different height with respect to the side trim.
- Height - B - should be same height as side trim to avoid jamming or damage when opening or closing trim.
Adjusting trim height - B -.
Adjusting gap dimension C and D
- Remove side trim. Refer to => [ Side Trim ] Pillar and Side Trims, Convertible.
- Remove bolts - 1 -.
- Align trim module - 2 - in the - direction of the arrow -.
- Tighten bolts to - 1 - to 3 Nm.
- Check gap dimension - C - and - D - for a distance of 3.5 to 4.5 mm and repeat the adjustment if necessary.
- Install side trim. Refer to => [ Side Trim ] Pillar and Side Trims, Convertible.
Adjusting trim height B
- Remove side trim. Refer to => [ Side Trim ] Pillar and Side Trims, Convertible.
- Remove the main frame of the lid module. Refer to => [ Small Trim Lid Module Assembly Overview ] Small Trim Lid Module Assembly Overview and => [ Large Trim Lid Module Assembly Overview ]. Item 7 Large Trim Lid Module Assembly Overview
- Remove bolts - 1 -.
- The height and angle in areas - A -, - B - and - C - can be changed by screwing bolts - 1 -, - 2 - and - 3 - in or out.
1 = A
2 = B
3 = C
- Tighten bolts to - 1 - to 3 Nm.
- Install the main frame of the lid module. Refer to => [ Small Trim Lid Module Assembly Overview ] Small Trim Lid Module Assembly Overview and => [ Large Trim Lid Module Assembly Overview ]. Item 7 Large Trim Lid Module Assembly Overview
- Check trim height - B - and readjust if necessary.
- Install side trim. Refer to => [ Side Trim ] Pillar and Side Trims, Convertible.