Checking I
Combination Valve, Checking
Requirements
- No malfunctions stored in DTC memory.
- Final control diagnosis performed, Adapting functions and components.
- Vacuum lines and hose unions must not leak.
Work sequence
NOTE: Do not use compressed air during the following check.
- Remove engine cover.
- Remove pressure hose (arrow) from secondary air pump motor.
NOTE: Press buttons on hose couplings together to release coupling.
- Blow lightly into pressure hose to combination valve.
Combination valve must be closed.
- Blow forcibly into pressure hose to combination valve.
Combination valve must open
If combination valve does not open or is continually open:
- Replace combination valve.