Secondary Air Injection (Air) Solenoid Valve -N112-, Checking - II
Secondary Air Injection (AIR) Solenoid Valve -N112-, Checking
Special tools and equipment
- V.A.G 1390 Hand vacuum pump
Check conditions
- No DTCs must be stored in DTC memory.
- Perform Output Diagnostic Test Mode (DTM)
- Vacuum lines and hose connections free of leaks.
- Vacuum lines not blocked/kinked.
Test sequence
- Disconnect vacuum hose -1- from Secondary air injection solenoid valve -2- -N112-.
- Connect hand vacuum pump V.A.G 1390 to vacuum hose -1-.
NOTE: Do not use compressed air during the following check.
- Disconnect pressure hose -3- from secondary air pump motor and blow in lightly -arrow-. Combi-valve must be closed.
NOTE: To release, press together the buttons on the hose coupling.
- Operate hand vacuum pump.
If the combi-valve does not open:
- Replace combi-valve