Measurement Check
Measurement check, 02M, 5 and 6 Spd. M/T
- Install measuring appliance and dial gauge
- Rotate input shaft so that tapered roller bearings settle.
- Press input shaft in direction of dial gauge.
- Bearing play: min. 0.065 to max. 0.150 mm.