FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Manufacturer's Scan Tool


Recirculating valve for turbocharger, checking
Valve opens between connection to intake manifold and connection to deceleration shutoff valve with no voltage Connection to vacuum reservoir is closed.

Test requirement
Not for engine code AUG
^ Output Diagnostic Test Mode (DTM) performed

Test sequence
- Switch ignition off.
- Disconnect connector from recirculating valve for turbocharger -N249-.





- Measure resistance between terminals of valve.
Specification: 25 to 35 ohms
If specified value is not obtained:
- Replace recirculating valve for turbocharger -N249-.