Reading Measured Value Block
Additional information
- Electrical Wiring Diagrams and Component Locations.
- Connect VAG 1551 Scan Tool and enter address word "02 transmission electronics". Advance until "Select function XX" indicated on display.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select "Read measured value block" function 08.
Indicated on display
Rapid data transfer Q
08 - Read measured value block
- Read measured value block
- Confirm entry with -Q- button.
Indicated on display
Read measured value block
Enter display group number XXX
- Enter display group number See List of selectable display group numbers.
- Confirm entry with -Q- button.
- 4 display fields always appear in the measured value block (in physical values if necessary). Decoding the individual values in display fields 1 to 4. Refer to "Electrical Testing (TCM Pinout Charts)".
Read measured value block ->
->1 ->2 ->3 ->4