with Manufacturer's Scan Tool
Combi-valve, checking
Special tools and equipment
^ VAG1390 Hand vacuum pump
Test conditions
^ No malfunction stored in DTC memory
^ Output Diagnostic Test Mode (DTM) carried out
^ Vacuum lines and hose connections free of leaks
^ Vacuum lines not blocked/kinked
Test sequence
- Remove engine cover.
- Pull vacuum hose -1- off secondary air injection solenoid valve -2- -N112-.
- Connect hand vacuum pump VAG1390 to vacuum hose -1-.
Note: Do not use compressed air during the following check!
- Remove pressure hose -arrow- between secondary air pump motor and connecting pipe and blow in with slight pressure.
Combi-valve must be closed.
Note: To release, press together the buttons on the hose coupling.
- Blow into pressure hose with light pressure -arrow-.
Combi-valve must be closed.
- Operate hand vacuum pump.
Combi-valve must open.
If the Combi-valve does not open:
- Replace corresponding Combi-valve.