Heating and Ventilation Controls, Removing and Installing
Removing
- Remove center air outlet console Service and Repair
- Remove mounting screws -arrows-.
- Lift out controls with cables from instrument panel in direction of -arrow A-.
- Detach cables from controls.
- Disconnect electrical connector.
With controls removed, check function of heating and ventilation cables as follows:
- Move cables in and out several times -arrow-.
- Replace damaged or stiff cables.
Installing
NOTE:
- Cable sleeves are color coded.
- All flaps must audibly move onto stops when turning controls.
- Always check cables before installing. Replace tight or damaged cables.
- Attach cable -1- to actuating arm -2- as indicated-arrow-.
- Press cable for footwell/defrost, cable for temperature flap and cable for central flap -1- into retainer -2- until it engages.
Cable color codes
- Footwell/defrost flap cable: green
- Central flap cable: yellow
- Temperature flap cable: beige
- Check and adjust cables. Refer to "Heating and Ventilation Cables, Installing and Adjusting" Adjustments
- Connect electrical connector
- Fit controls into instrument panel opening and install mounting screws.