With Manufacturer's Scan Tool
Recirculating Valve For Turbocharger -N249-, Checking
Special tools and equipment
- Hand multimeter VAG 1526 or multimeter VAG 1715
- Adapter set VAG 1594
Test conditions
- Perform Output Diagnostic Test Mode (DTM):
Test sequence
- Switch ignition off.
- Disconnect connector of Recirculating valve for turbocharger -N249-.
- Measure resistance between valve terminals.
Specification: 27 to 30 Ohms
If the specification is not obtained:
- Replace Recirculation valve for turbocharger -N249-.
- Check DTC memory.
- Read readiness code.
- Generate readiness code again if DTC memory has been erased or engine control module separated from permanent positive.