Display Groups 110 to 119 (Charge Pressure Control)
Measuring Value Blocks, Evaluating Display Groups 110 To 119 (Charge Pressure Control)
Display group 111 - Charge pressure control - adaptation valves for boost pressure limitation
Display Group 111:
Display group 113 - Charge pressure control
Display Group 113:
Evaluating display group 113, display zone 4 - atmospheric pressure
Elevation Air pressure
0 m 998 mbar
500 m 954 mbar
1000 m 902 mbar
1500 m 853 mbar
2000 m 805 mbar
2500 m 756 mbar
3000 m 704 mbar
3500 m 655 mbar
4000 m 607 mbar
NOTE: The air pressure can fluctuate depending upon the atmospheric conditions.
Display group 114 (Charge pressure control)
Display Group 114:
Display group 115 (Charge pressure control)
Display Group 115:
Display group 116 (Charge pressure control)
Display Group 116:
Display group 117 (Charge pressure control)
Display Group 117:
Display group 118 (Charge pressure control)
Display Group 118:
Display group 119 (Charge pressure control)