On Board Diagnostic (OBD) For Radio-Frequency Remote Control For Central Locking, Initiating
On Board Diagnostic (OBD) For Radio-frequency Remote Control For Central Locking, Initiating
Test requirements:
- All fuses OK according to wiring diagram.
- Battery voltage at least 9 volts.
NOTE:
- If nothing is indicated on display, check voltage supply for Fault read out device V.A.G 1551 according to wiring diagram, => Electrical Wiring Diagrams, Troubleshooting and Component Locations
- Depending on program, additional operating information can be printed out by pressing HELP button of Fault read out device V.A.G 1551.
- --> -button is used for advancing through program sequence.
- PRINT button is used for switching on printer (lamp in button illuminates).
- Fault read out device V.A.G 1551, connecting.
- Switch on ignition.
Indicated on display:
Rapid data transfer HELP
Enter address word XX
- Press buttons - 3 - and - 5 - (35 is address word for vehicle system to be tested, "central locking system").
Indicated on display after entering address word 35:
Rapid data transfer Q
35 Central locking
- Press Q button to confirm input.
and then following is indicated:
Indicated on display:
Rapid data transfer
Scan tool sends address word 35
Fault read out device V.A.G 1551 scan tool display displays control module identification, e.g.:
7D0 959 800 B Radio-frequency control module 0001->
Coding 00001 WSC XXXXX
- Press --> -button.
Indicated on display:
Rapid data transfer HELP
Select function XX