Fuel Distance/Mileage Module: Service and Repair
Adaptation (function 10)
Use this function to initiate and store the following changes:
- Adaptation of odometer reading when replacing/exchanging instrument cluster.
- Adaptation of fuel gauge reading.
- Adaptation of Multi-function Indicator (MFA) fuel consumption indicator (where applicable).
Individual functions are called up using the appropriate channel number from adaptation table.
Adaptation table:
Multi-function Indicator (MFI) Fuel Consumption Indicator, Adaptation
NOTE:
- Consumption indicator can only be adapted once between 85% and 115%.
- Value must be entered in steps of 5%.
- Connect scan tool VAG 1551, select operating mode 1 "Rapid data transfer", switch on ignition and enter address word 17 "instrument cluster".
- Press -Q- button to confirm input.
- Press -> button until "Select function" appears in display.
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press buttons -1- and -0- to select "Adaptation" function 10.
Indicated on display:
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display:
Adaptation
Enter channel number XX
- Press buttons -0- and -3- to select adaptation "channel 03".
- Press -Q- button to confirm input.
Indicated on display:
Channel 03 Adaptation 100 ->
<-1 3->
- Press -> button to continue.
NOTE: Correction of fuel consumption display is only possible via direct input.
Indicated on display:
Channel 03 Adaptation 100
Enter adaptation value XXXXX
- Input desired correction value using scan tool button pad, filling initial positions with "0".
Example:
Desired input value: 90% = button pad entry: 00090
Indicated on display:
Channel 03 Adaptation 100 Q
Enter adaptation value 00090
- Press -Q- button to confirm input.
Indicated on display:
Channel 03 Adaptation 90 Q
<-1 3->
- Press -Q- button to confirm input.
Indicated on display:
Channel 03 Adaptation 90 Q
Store changed value?
- Press -Q- button to confirm input.
Indicated on display:
Channel 03 Adaptation 90 ->
Changed value is stored
- End consumption indicator adaptation with -> button.
Indicated on display:
Rapid data transfer HELP
Select function XX
NOTE: A false entry switches the tester to "Select function" mode.
If the following display appears:
Function Is unknown or ->
cannot be carried out at the moment
- Press -> button.
- Select function "10 - Adaptation" and adaptation channel 03 again.
- Carry out corrections to consumption indicator and confirm with Q button.