Fuel Distance/Mileage Module: Service and Repair




Adaptation (function 10)

Use this function to initiate and store the following changes:
- Adaptation of odometer reading when replacing/exchanging instrument cluster.
- Adaptation of fuel gauge reading.
- Adaptation of Multi-function Indicator (MFA) fuel consumption indicator (where applicable).

Individual functions are called up using the appropriate channel number from adaptation table.

Adaptation table:







Multi-function Indicator (MFI) Fuel Consumption Indicator, Adaptation


NOTE:
- Consumption indicator can only be adapted once between 85% and 115%.
- Value must be entered in steps of 5%.


- Connect scan tool VAG 1551, select operating mode 1 "Rapid data transfer", switch on ignition and enter address word 17 "instrument cluster".
- Press -Q- button to confirm input.
- Press -> button until "Select function" appears in display.

Indicated on display:


Rapid data transfer HELP
Select function XX



- Press buttons -1- and -0- to select "Adaptation" function 10.

Indicated on display:


Rapid data transfer Q
10 - Adaptation



- Press -Q- button to confirm input.

Indicated on display:


Adaptation
Enter channel number XX



- Press buttons -0- and -3- to select adaptation "channel 03".
- Press -Q- button to confirm input.

Indicated on display:


Channel 03 Adaptation 100 ->
<-1 3->



- Press -> button to continue.


NOTE: Correction of fuel consumption display is only possible via direct input.


Indicated on display:


Channel 03 Adaptation 100
Enter adaptation value XXXXX



- Input desired correction value using scan tool button pad, filling initial positions with "0".

Example:
Desired input value: 90% = button pad entry: 00090

Indicated on display:


Channel 03 Adaptation 100 Q
Enter adaptation value 00090



- Press -Q- button to confirm input.

Indicated on display:


Channel 03 Adaptation 90 Q
<-1 3->



- Press -Q- button to confirm input.

Indicated on display:


Channel 03 Adaptation 90 Q
Store changed value?



- Press -Q- button to confirm input.

Indicated on display:


Channel 03 Adaptation 90 ->
Changed value is stored



- End consumption indicator adaptation with -> button.

Indicated on display:


Rapid data transfer HELP
Select function XX



NOTE: A false entry switches the tester to "Select function" mode.


If the following display appears:


Function Is unknown or ->
cannot be carried out at the moment



- Press -> button.
- Select function "10 - Adaptation" and adaptation channel 03 again.
- Carry out corrections to consumption indicator and confirm with Q button.