FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Work Procedure


Use VAG 1551 scan tool to check the air bag ECM part number application:

- If part number reads 6N0 909 601 D, no replacement is necessary





- If the part number reads 701 909 601 D, followed by code "MASKE3" (Illustration A), no replacement is necessary





- If the part number reads 701 909 601 D, followed by a code other than "MASKE3" or is blank (Illustration B), carefully replace the unit with a new ECM part number 701 909 603 D or 6N0 909 601 D after disconnecting battery ground strap

CAUTION:

^ Disconnect battery ground (GND) strap before removing air bag ECM

^ Do not break harness connector clip

^ Handle ECM very carefully

^ Protect radio code

- After installation of a new air bag ECM, set ECM to basic setting with VAG 1551 scan tool and follow with a complete functional test





- If the module coding reads "00000" instead of "00068" (see Illustration C ) coding must be updated

Air Bag ECM Coding Change Procedure

Important:
In order to code the air bag control module, your dealer number must be present in the 1551 scan tool.

V.A.G. 1551 Scan Tool Display:





Framed text appears on display;

* appears alternately

^ Input mode 4 then push Q button

Display appears as shown:

Dealership code HELP
1-Display 2-Delete 3- Enter


^ Push HELP button for instructions to enter your dealership number or enter 3 to input dealer code

- Continue updating air bag ECM coding as follows:

^ Press -> button.

Display appears as shown:

Rapid data transfer HELP
Select function XX


^ Press buttons 0 and 7 to select the "Code Control Module" function

Display appears as shown:

Rapid data transfer Q
07 - Code Control Module


^ Acknowledge input with Q button

Display appears as shown:

Code Control Module Q
Enter code number XXXXX


^ Enter code number -00068-

Note:
Air Bag Control Module code number 00068 applies only to Golf, Jetta and Cabrio vehicles.

^ Acknowledge input with Q button

^ Press -> button.

Display appears as shown:

Rapid data transfer HELP
Select function XX


^ Press buttons 0 and 6 to select the "End Output" function.

Display appears as shown:

Rapid data transfer Q
06 - end output


^ Acknowledge input with Q button

^ Reset to basic setting

^ Perform complete functional test. including accessories